Cookies CSS
Tuesday, December 6, 2016
Extension Groups, Search Best Practices in Bridge Operator Console
Bridge Operator Console provides a number of different way to find system users. For best performance we recommend never displaying more items on the screen that absolutely necessary. If you chose put 150 users on the screen, your PC will use the resources required to update 150 in real-time despite only being able to see 20 or so at most at one time.
Best Methods for Finding Users
1. Predictive Transfer
Enabling predictive transfer unleashes the power of 5 machine learning algorithms to present the most likely destination for a given caller. This feature reduces lookup time far beyond any other method or any other product on the market.
2. Searching
When a call becomes active the cursor is put in the search box. A user can then start typing any part of a users first name, last name, title, department or phone number. The extensions list will quickly filter to match the search.
3. Extension Group Scrolling (Slowest and not recommended)
Users can select an extension group to find a group of users in a particular department or location for example. While this method does work, it is much slower than using the combination of search and related people. The list is limited to 200 results by default. If you require more you can change the SearchLimit regkey in the program to override it, but this is not a recommended procedure.
You can find more information here.
Searching and Extension Groups
Thursday, July 14, 2016
AXL issues or high CPU utilization on CallManager after applying Windows update to BOC Server
After applying Microsoft KB3161608, you may experience issues with AXL connecting to CallManager.
Additional symptoms may be high CPU spikes on the CUCM providing AXL services to the BOC server.
There seems to be a known issue in Tomcat which is fixed in a newer versions
https://bz.apache.org/bugzilla/show_bug.cgi?id=52511
Currently, we are recommending the removal of KB3161608 followed by applying any other remaining Microsoft updates.
UPDATE: KB3172605 appears to replace KB3161608 and has the same issues.
Additional symptoms may be high CPU spikes on the CUCM providing AXL services to the BOC server.
There seems to be a known issue in Tomcat which is fixed in a newer versions
https://bz.apache.org/bugzilla/show_bug.cgi?id=52511
Currently, we are recommending the removal of KB3161608 followed by applying any other remaining Microsoft updates.
UPDATE: KB3172605 appears to replace KB3161608 and has the same issues.
Thursday, June 9, 2016
Manual License Update
If your server is blocked from accessing the internet to update its license there is a manual process to complete it.
Go to the License Update Generator website. You will need to enter your Product License key and answer the Captcha.
A SQL script will be generated in red at the bottom of the page.
Copy this script to Notepad.
Click here for License Update Generator

Open the BOC Phone System Settings tool.
Choose the Utilities tab -> Database Queries -> Run SQL Query
Paste the SQL Script as shown, and the click Execute SQL Query
After a few moments, the license should reflect correctly in the Phone System Settings tool in the lower right corner.
Go to the License Update Generator website. You will need to enter your Product License key and answer the Captcha.
A SQL script will be generated in red at the bottom of the page.
Copy this script to Notepad.
Click here for License Update Generator
Open the BOC Phone System Settings tool.
Choose the Utilities tab -> Database Queries -> Run SQL Query
Paste the SQL Script as shown, and the click Execute SQL Query
After a few moments, the license should reflect correctly in the Phone System Settings tool in the lower right corner.
Wednesday, June 8, 2016
Configure BLOC for Exchange on o365
If you are using Outlook and Exchange as part of Office 365 (o365), you may need to manually configure the Exchange Connection in the settings.
Follow the Exchange Connecting Settings example below.
1. Uncheck Use Currently Logged In User
Leave the EWS Domain empty
2. Uncheck Use Autodiscover URL
The EWS URL should be https://outlook.office365.com/EWS/Exchange.asmx
3. Fill in the EWS User and EWS Password with your o365 email credentials.
Follow the Exchange Connecting Settings example below.
1. Uncheck Use Currently Logged In User
Leave the EWS Domain empty
2. Uncheck Use Autodiscover URL
The EWS URL should be https://outlook.office365.com/EWS/Exchange.asmx
3. Fill in the EWS User and EWS Password with your o365 email credentials.
Sunday, May 1, 2016
Bridge Operator Console for Cisco - Connector Specs
BOC Connector running in Stand Alone - Recommended Hardware Specs
If you have a single operator install you may choose to run the
connector software on the same machine as the client. If this
is the case you may use the recommended hardware specs below as a
recommendation, although it may vary given the numbers of phones,
activity, and other concurrently running applications on that
machine.
Intel i5 Quad Core CPU
4GB of Memory
100GB of Free HD Space (C: Drive)
BOC Connector running on a Server - Recommended Hardware Specs
The BOC Connector is a Windows service
that connects to your phone system, and a MS SQL Database. Here are the suggested build outs.
The roles change based on whether or not you deploy SQL
(may need more memory or processor) on box or whether you
run the mobile or WIndows client in socket mode.
Additionally, only CUCM 8.5 with update 1 and later have a TSP
Driver that
supports 64 Bit. And to compound that, the 32 Bit TSP
from Cisco is not supported on a 64 Bit platform (ie,
doesn’t work). So you cannot build out a 64Bit machine
in anticipation of a 8.5U1 (or later) rollout and have it work on a
pre-8.5U1 CUCM.
|
|||||||||||||||||||||||||||||||||||||||||||||||||
Suggested Minimum Server Specifications
Any Windows version supported by the CUCM TSP version (32 or 64 if TAPI Supports it)
|
|||||||||||||||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||||||||||||
* Servers may need additional
resources with a high number of users running in socket
mode, or in extremely high call volume situations.
|
|||||||||||||||||||||||||||||||||||||||||||||||||
Server can be either Physical or
Virtual, although we prefer virtual, because it answer all
of the high availability questions. For the OS, you
can run all of the latest Microsoft recommended service
packs and hotfixes. If you decide to install SQL
Express on the box, there may be some MS required support
software that needs to be installed. Generally
speaking, we are not very fussy on what is there as long as
it is reasonably current.
|
|||||||||||||||||||||||||||||||||||||||||||||||||
Bridge Operator Console for Cisco Client Specs
Recommended BOC Client Specs
Bridge Operator Console 3.x for Windows
Win Vista, Win 7, Win 8
.Net 4.5 Quad Core CPU or Better 2GB of Ram or Better |
Bridge Operator 2.x for Windows
Win XP
SP3, Win Vista, Win 7, Win 8
.Net 3.5 SP1 Dual Core (non Centrino) CPU or Better 2GB of Ram or Better |
Bridge Operator Console 1.x for Apple Ipad
IOS 5.0 or Better
|
Bridge Operator Console 2.x for Android
Android 2.3 or Better
|
Bridge Communications provides only
the recommended hardware specifications, and not any
minimums. The minimum requirements for an organization
that has 100 phones, would be dramatically different from
one that has 25,000. In most cases any fairly modern
desktop PC will provide adequate power to run our
application. We recommend you always get a 60
day demo key and try the product on your existing hardware
before purchasing.
|
|
Saturday, April 30, 2016
Supported Operating Systems - Bridge Operator Console for Windows 2.x/3.x for Cisco
Supported Operating Systems - Bridge Operator Console for Windows 2.x/3.x
Below is a matrix of supported client operating systems based on
the version of CUCM.
Bridge Operator Console relies on the Cisco TSP driver for
it's real time call information and control.
Prior to CUCM 8.5 U1 there was no support for this driver in Windows
7 or any 64 bit OS. With CUCM 8.5 U1 and
beyond BOC is supported for production in any Windows 7 or 64 bit OS environment.
beyond BOC is supported for production in any Windows 7 or 64 bit OS environment.
Testing before CUCM Upgrade
BOC offers a SQL based and Socket based mode when the TSP isn't available, to allow "proof of concept" type testing
where an organization would like to test the features before a CUCM upgrade. Performance will not be as true as
if the TSP were installed, but should be sufficient on a small scale to determine functionality in your environment.
*Connection speeds and geography can slow performance when the TSP is not available for your OS.
BOC offers a SQL based and Socket based mode when the TSP isn't available, to allow "proof of concept" type testing
where an organization would like to test the features before a CUCM upgrade. Performance will not be as true as
if the TSP were installed, but should be sufficient on a small scale to determine functionality in your environment.
*Connection speeds and geography can slow performance when the TSP is not available for your OS.
Green = Supported in a Production Environment, Yellow =
Supported for Proof of Concept before Upgrading CUCM, Red =
Unsupported by Cisco.
| TSP Availability | Windows XP SP2 32bit | Windows XP SP2 64bit | Windows Vista 32bit | Windows Vista 64bit | Windows 7 32bit | Windows 7 64bit | Windows 8 32bit | Windows 8 64bit | Windows 8.1 | Windows 10 |
| CUCM 6.x | ||||||||||
| CUCM 7.x | ||||||||||
| CUCM 8.0 | ||||||||||
| CUCM 8.5 | ||||||||||
| CUCM 8.5 U1 | ||||||||||
| CUCM 8.6 | ||||||||||
| CUCM 9.0 | ||||||||||
| CUCM 9.1 | ||||||||||
| CUCM 10.0 | ||||||||||
| CUCM 10.5 | ||||||||||
| CUCM 11.0 | ||||||||||
| CUCM 11.5 |
Server Versions Supported
| TSP Availability | Windows 2008 32 bit | Windows 2008 and R2 64 bit | Windows 2012 and R2 64 Bit |
| CUCM 6.x | |||
| CUCM 7.x | |||
| CUCM 8.0 | |||
| CUCM 8.5 | |||
| CUCM 8.5 U1 | |||
| CUCM 8.6 | |||
| CUCM 9.0 | |||
| CUCM 9.1 | |||
| CUCM 10.0 | |||
| CUCM 10.5 | |||
| CUCM 11.0 | |||
| CUCM 11.5 |
Monday, January 18, 2016
Extended AD information missing
If you are using some of the more extended AD attributes such as Assistant or Secretary fields, the may not be gathered during a full LDAP build if you are pointing at an AD entry point other than the default at TCP/389.
Some installations require contacting various AD replicas such as a Global Catalog server (GC at TCP/3268) or a Lightweight Directory Service (LDS). These are not always complete replicas and will not provide the more obscure attributes. However, it may be possible that they can be added to replicas. Work with your Active Directory support team as needed.
Some installations require contacting various AD replicas such as a Global Catalog server (GC at TCP/3268) or a Lightweight Directory Service (LDS). These are not always complete replicas and will not provide the more obscure attributes. However, it may be possible that they can be added to replicas. Work with your Active Directory support team as needed.
CTI issues with Park DNs
CallManager allows you to create Park positions in a couple of ways.
The most common is an all numeric numbering plan.
Example:
Example:
5000
500[0-9]
500X
However, it is possible to create Park positions with non-numeric characters.
While these can still function as park positions, CallManager will not provide proper CTI information on those positions. Furthermore, it has been noted that if there are a very large number of these, the Cisco TSP from CallManager 10.5.2 will crash providing no CTI for any DNs.
Examples:
*5000
#5000
*500[0-9]
*500X
Bridge Communication Operator Console only supports all numeric globally unique park DN's.
Friday, October 30, 2015
Active Directory integration with multiple trees in a single forest.
If you have the need to integrate with an Active Directory that comprises of two or more trees in the same forest, certain adjustments will need to be made.
For example:
You have two AD trees.
corp.ndbridge.com represented by DC=corp,DC=ndbridge,DC=com
uk.ndbridge.com represented by DC=corp,DC=ndbridge,DC=com
These trees exist in the forest ndbridge.com
In this case, you will need to point our server at a global catalog server to be able to walk down the necessary trees. You will see that below denoted by the IP address of the global catalog server and the port the GC is answering on. TCP 3268 is the default.
For example:
You have two AD trees.
corp.ndbridge.com represented by DC=corp,DC=ndbridge,DC=com
uk.ndbridge.com represented by DC=corp,DC=ndbridge,DC=com
These trees exist in the forest ndbridge.com
In this case, you will need to point our server at a global catalog server to be able to walk down the necessary trees. You will see that below denoted by the IP address of the global catalog server and the port the GC is answering on. TCP 3268 is the default.
Thursday, October 22, 2015
Gathering Lync/Skype Diagnostics
Gathering diagnostics logs will aid in troubleshooting issues.
You may need to turn on some options in the Lync/Skype client for the logs to be created.
Go into your Skype for Business client options and verify the option is chosen.
When you have verified this in in place, re-create the conditions you are trying to capture.
When this is completed, you will need to exit the BLOC console and the Lync\Skype client.
Then open the users APPDATA folder. You can do this by opening Explorer and typing %APPDATA% into the navigation bar.
Then navigate up one level and then down the Local path until you get to the Tracing folder.
The path will be something like this...
The primary file we will need is Lync-UccApi-0.UccApilog.
Your Lync/Skype must be closed or you will not be able to access this file.
Email this file to support@bridgeoc.com with your Customer name in the subject line.
We would also like you to send the Windows Application Event log.
Open Windows Event Viewer. Navigate to the Windows Logs -> Application
Right click on the Application log and choose Save All Events As
Leave it in EVTX format.
Give it a name and save this somewhere you can retrieve it to email to support@bridgeoc.com as well.
You may need to turn on some options in the Lync/Skype client for the logs to be created.
Go into your Skype for Business client options and verify the option is chosen.
When you have verified this in in place, re-create the conditions you are trying to capture.
When this is completed, you will need to exit the BLOC console and the Lync\Skype client.
Then open the users APPDATA folder. You can do this by opening Explorer and typing %APPDATA% into the navigation bar.
Then navigate up one level and then down the Local path until you get to the Tracing folder.
The path will be something like this...
C:\Users\<USERS NAME>\AppData\Local\Microsoft\Office\15.0\Lync\Tracing
The primary file we will need is Lync-UccApi-0.UccApilog.
Your Lync/Skype must be closed or you will not be able to access this file.
Email this file to support@bridgeoc.com with your Customer name in the subject line.
We would also like you to send the Windows Application Event log.
Open Windows Event Viewer. Navigate to the Windows Logs -> Application
Right click on the Application log and choose Save All Events As
Leave it in EVTX format.
Give it a name and save this somewhere you can retrieve it to email to support@bridgeoc.com as well.
Friday, October 2, 2015
Indexing Active Directory Telephone Number or IP Phone numbers
To install the Active Directory Schema snap-in
- Open Command Prompt.
- Type:
regsvr32 schmmgmt.dll
This command will register Schmmgmt.dll on your computer. For more information about using regsvr32, see Related Topics. - Click Start, click Run, type mmc /a, and then click OK.
- On the File menu, click Add/Remove Snap-in, and then click Add.
- Under Available Standalone Snap-ins, double-click Active Directory Schema, click Close, and then click OK.
To index an attribute in Active Directory
- Open the Active Directory Schema snap-in.
- In the console tree, click Attributes.
Where?- Active Directory Schema/Attributes
- In the details pane, right-click the attribute that you want to index, and then click Properties.
- Click Index this attribute in the Active Directory.
Subscribe to: